dures® A451 wear rings and bushings installed in lean carbonate circulation pump resulted in an $800,000 increase in yearly production

After a debottlenecking project in a hydrogen manufacturing plant, adequate lean carbonate circulation could not be maintained for maximum feed rates. The 4 stage 1500 HP pump was being driven by a power recovery turbine, but the flow rate was insufficient for the process. Two paths were identified to solve the problem: purchase a larger capacity pump or maximize the efficiency of the existing equipment.